Consultor Eletrônico



Kbase P100030: Progress session GPF when adding the Repository Explorer Control 10.0 or 11.0 to a Progress window
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   5/19/2006
Status: Verified

FACT(s) (Environment):

Progress 9.1D
Progress 9.1E
OpenEdge 10.0x
OpenEdge 10.1A
Crystal Reports 10
Crystal Reports 11 (XI)

SYMPTOM(s):

Progress session GPF when attempting to use Crystal Repository Explorer Control 10.0

Progress session GPF when trying to use Business Objects Enterprise Repository Explorer Control 11.0

Session GPF as soon as the control is added to a window

Affects normal Windows and SmartWindows

Stack trace from prowin32.exe from Progress 9.1D/E reads:

CWRXFile::~CWRXFile+XXXX
CWRXFile::~CWRXFile+XXXX
CWRXFile::~CWRXFile+XXXX
OrdinalXXXX+XXX
OrdinalXXXX+XXX
utConvertToIx+XXXXX
utConvertToIx+XXXXX

Stack trace from prowin32.exe from OpenEdge 10.0B reads:

prox.dll
prox.dll
prox.dll
OrdinalXXXX+XXX
OrdinalXXXX+XXX
dbut_utfree+XXXX
dbut_utfree+XXXX

Stack trace from OpenEdge 10.1A reads:

prox.dll
prox.dll
prox.dll
OrdinalXXXX+XXX
OrdinalXXXX+XXX
utConvertToIx+XXXX
utConvertToIx+XXXX

No problems using Crystal Repository Explorer Control 10.0 in Visual Basic .NET

CAUSE:

These OCX's were not intended for use outside of Crystal products.

FIX:

Do not use the Crystal Repository Explorer Control 10.0 and the Business Objects Enterprise Repository Explorer Control 11.0 outside of Business Objects products.