Consultor Eletrônico



Kbase P108904: OpenEdge Architect: Running procedure in OpenEdge perspective displays incomplete error message 4673
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   1/30/2006
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.1A

SYMPTOM(s):

OpenEdge Architect: Running procedure in OpenEdge perspective displays incomplete error message 4673

Running .p procedure from OpenEdge perspective produces truncated error message 4673

** An unidentified error occured on call <call>,filename <file>, routine <routine>,linenumber <linenumber>,error <error>,state <state>. (4673)

Example of the truncated error message: umber 14472, error -16648, state -16648 (4673)

Another OpenEdge version installed on the same machine

CAUSE:

Project's OpenEdge, Runtime Startup parameters contains -ininame pointing to the
ini file from another OpenEdge version

FIX:

The %DLC%\bin\progress.ini file from the correct OpenEdge release needs to
be copied into the working directory and appropriate modifications made to it
taking care that DLC and PROPATH settings reflect correct directory locations.
Once that has been done, use that ini file in the project's OpenEdge Runtime Startup parameters.