Kbase P44742: Cannot convert to . (7177) while sending messages through the SonicMQ Adapter
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  16/10/2008 |
|
Status: Unverified
FACT(s) (Environment):
Progress 9.1D
SYMPTOM(s):
Error when publishing a message through the SonicMQ Adapter.
java.lang.Error: Bad data type
Cannot convert <data type> to <data type>. (7177) while sending messages
CHANGE:
Migrated from 9.1C to 9.1D
CAUSE:
Classpath is not set properly in setenv.sh
FIX:
Make modifications to the Classpath in setenv.sh and restart the AdminServer.