Consultor Eletrônico



Kbase P105040: Incorrect values are stored for the WSA idleSessionTimeout and connectionLifetime properties
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   6/6/2005
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.0B
Web Services

SYMPTOM(s):

Incorrect values are stored for the WSA idleSessionTimeout and connectionLifetime properties

The WSA idleSessionTimeout and connectionLifetime properties read the input values as hexadecimal values instead of decimal values.

Modifying the WSA idleSessionTimeout property will cause the connectionLifetime property value to chance and vice versa.

Modifying the WSA idleSessionTimeout and connectionLifetime properties through Progress Explorer.

CAUSE:

This is a known issue being investigated by Development

FIX:

Manually modify the values in the corresponding Web Service's .props file in the JSE webapps directory.