SYMPTOM(s):

Error 8013, 8014, 1252 and 1451 when trying to connect to the 9.2 32-bit Oracle database through OE 10.0B 64-bit to Oracle DataServer

Could not open Dynamic Library: $ORACLE_HOME/lib/libclntsh.so (8013)

DLL Error : ld.so.1: $DLC/bin/_progres: fatal:$ORACLE_HOME/lib/libclntsh.so: wrong ELF class:ELFCLASS32 (8014)                       

ORACLE error -1012 see "ORACLE Error Messages and Codes Manual". (1252)

Failed to connect to ORACLE database <db_name>. (1451)

FACT(s) (Environment):

Solaris SPARC 9
OpenEdge 10.0B 64-bit
Oracle DataServer
Oracle 9.2 database is 32-bit

CAUSE:

The OpenEdge 10.0B 64-bit DataServer executable is trying to link with the Oracle's client library (libclantsh.so) which is 32-bit.  Therefore the above error is apparent.

FIX:

Install 64-bit Oracle 9.2 database