Kbase P65646: Using Progress with high resolution, getting error 4132
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  12/04/2008 |
|
Status: Verified
FACT(s) (Environment):
Progress 9.x
OpenEdge 10.x
Dynamics
SYMPTOM(s):
Error 4132 occurs when starting Progress with high resolution displays
Screen resolution is set to high resolution (= more than 1600 pixels wide)
** Invalid character unit value <value>, Changed to 320. (4132)
Starting the AppBuilder displays error 4132
Opening a New Procedure Window from AppBuilder triggers error 4132
error 4132 opening a Window in the AppBuilder
error 4132 starting the Procedure Editor
error 4132 opening a Dialog-Box in the AppBuilder
double-click a .w File from Windows Explorer results in error 4132
opening a .p, .i File from Windows Explorer brings up a Character Progress Window behind the Procedure Editor with a 4132 Message in the Message Area of the Window
CAUSE:
Bug# 20040302-007
FIX:
Upgrade to Progress 9.1E01 or later
Upgrade to OpenEdge 10.0B01 or later
Upgrade to Dynamics 2.1B or later