Consultor Eletrônico



Kbase P103918: 10.0B 64-bit Progress is no longer clearning pending connections
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   16/02/2009
Status: Unverified

SYMPTOM(s):

9.1E 64-bit Progress is no longer clearning pending connections

10.0B 64-bit Progress is no longer clearning pending connections

FACT(s) (Environment):

All Supported Operating Systems
Progress 9.1E 64-bit
OpenEdge 10.0B 64-bit

CAUSE:

Bug# 20050228-016

CAUSE:

Bug# OE00113967

CAUSE:

On 64 bit systems, time will return 8 bytes, not 4, and if the time is returned to an address, it can corrupt memory.

Certain functions which did pointer comparisons to time functions would not get the proper returned value (such as the PendConnTime algorithm) and would not appropriately complete their designed functionality.

FIX:

This issue was fixed in Service Pack 9.1E02 and 10.0B02 where a correction was made to appropriately handle 8 byte time function on 64-Bit versions of Progress.