Consultor Eletrônico



Kbase P103300: Error 5635 after ADM1 application upgrade to OpenEdge 10
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   4/15/2005
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.x

SYMPTOM(s):

Error 5635 after upgrade to OpenEdge 10

SYSTEM ERROR: -s exceeded. Raising STOP condition and attempting to write stack trace to file 'procore'. Consider increasing -s startup parameter. (5635)

ADM1 application recompiled in OpenEdge 10 runs but intermittently fails with error 5635.

CAUSE:

stack size parameter set too low.

FIX:

Increasing the -s parameter. In this case it was increased from 200 to 800.