Kbase P101813: Crystal Reports 10 Report Viewer ActiveX control causes GPF
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  3/7/2005 |
|
Status: Unverified
FACT(s) (Environment):
Progress 9.x
OpenEdge 10.x
Crystal Reports 10
SYMPTOM(s):
Window contains instance of Crystal Report Viewer
Installed CRAXDRT.DLL version 10.0.5.868 from Crystal
GPF happens when the window is loaded the second time within a Progress session
CAUSE:
The GPF is caused by a memory allocation failure within the new version of Crystal's CRAXDRT.DLL
FIX:
Contact Crystal Technical Support to obtain a newer version of the DLL which fixes this problem. Version 10.0.5.955 has been reported by customers as working properly.