Consultor Eletrônico



Kbase P96807: Error# 1006 when trying to run a Webclient program - check connection parameters
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   21/12/2004
Status: Unverified

FACT(s) (Environment):

Windows

SYMPTOM(s):

Error 1006 when running a deployed WebClient application

<program name> Database <dbname> not connected. (1006)

CAUSE:

The application.wcp contained a typo in one of the startup parameters being passed from the WebClient application Assembler Startup parameters box.

FIX:

To resolve the problem perform the following:

1. Fix the typo in the application.wcp
2. Regenerate the cab files
3. Replace the newly generate files onto the WebServer.