Consultor Eletrônico



Kbase P79999: Passing ProDataSet to AppServer as input-output parameter crashes session
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   04/11/2004
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.0A

SYMPTOM(s):

Passing ProDataSet to AppServer as input-output parameter crashes session

"0x10102576" referenced memory at "0x00000000". The memory could not be "read".

Dataset is passed as input-output by-value parameter (no by-reference specified) to internal procedure

Dataset is passed as input-output parameter to AppServer procedure from internal procedure

Dataset has data-relation defined

CAUSE:

Bug# 20040511-002

FIX:

Upgrade to 10.0B or later release