Consultor Eletrônico



Kbase P100812: FILE-INFO:FILE-TYPE returns unknown (?) when run in a batch script from ProControl
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   04/08/2005
Status: Unverified

FACT(s) (Environment):

Windows

SYMPTOM(s):

ProControl

Running a batch script

FILE-INFO:FILE-TYPE returns unknown (?) when launched from ProControl Other Tasks

FILE-INFO:FILE-TYPE returns DRW when the same code is run from Procedure Editor

Target of FILE-INFO:FILE-TYPE is a folder on a remote network drive

CAUSE:

Using Local System User to start the ProService service. This user account does not have sufficient permissions to access the remote drive.

FIX:

Ensure that the user account being used to start the ProService has permissions to access the network drive.