Kbase P95225: Error 5893 When starting V9 appbuilder
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  9/22/2004 |
|
Status: Unverified
FACT(s) (Environment):
Progress 9.1D
SYMPTOM(s):
Error 5893 When starting V9 appbuilder
Error: The automation server for <automation object name> is not registered properly.
Please reinstall this server or try registering it again. (5893)
Error: The automation server for PROX.PROIDE is not registered properly.
Please reinstall this server or try registering it again. (5893)
OpenEdge 10 has just been installed and this starts without a problem. But since this installation, the Progress 9.1D Appbuilder fails to start with error 5893.
CAUSE:
The automation server for 9.1D PROX.PROIDE is not registered properly.
FIX:
Register the version 9.1D prox.dll with:
regsvr32 <path>/dlc/bin/prox.dll