Consultor Eletrônico



Kbase P85795: WebSpeed application causes unable to run web object error in the browser after the WebSpeed Transac
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/14/2004
Status: Unverified

FACT(s) (Environment):

WebSpeed 3.1D
OpenEdge 10.0A
Windows XP
RedHat Linux Advanced Server 3.0

SYMPTOM(s):

Unable to run web object error in the browser

WebSpeed code resides in Linux

Uses SAMBA to map the drive

The drive can be browsed from the WebSpeed workshop > PROPATH

WebSpeed page stops functioning when the speedscript tag is encountered

Same problem is seen when code resides on the same machine

Uses a customized .p file in the WebSpeed agent startup parameter

The customized .p file runs web-disp.p file and another .p file that sets the PROPATH for the WebSpeed agents

CHANGE:

Upgraded the WebSpeed 3.1D to OpenEdge Release 10.0A

CAUSE:

Cause is unknown at the moment, but the problem is not apparent with the Service pack 10.0A01.

FIX:

Install the Service Pack 10.0A01.