Kbase P10542: Error 795 socket = 16, ret -1 , errno 232 after ending attempt to connect
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  3/17/2010 |
|
Status: Verified
SYMPTOM(s):
Error 795 socket = 16, ret -1 , errno 232 after ending attempt to connect
Error reading socket = 16, ret -1 , errno 232 (795)
ODBC connection hangs
FACT(s) (Environment):
Database started using _mprosrv
MERANT 3.60 32-BIT Progress SQL-92
All Supported Operating Systems
Progress 9.X
CAUSE:
The exact cause is unknown at the time of this writing
FIX:
Start database using PROSERVE instead of _mprosrv