Consultor Eletrônico



Kbase P92221: Roll Forward fails with error 833
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   20/08/2004
Status: Unverified

SYMPTOM(s):

Roll forward fails with date mismatch

** Those dates don't match, so you have the wrong copy of one of them. (833)

CAUSE:

The cron job which copies the ai files to a directory from which the roll forward cron job finds ai files to roll forward failed due to out of disk space errors. As a result, the backup - ai note pairs were out of synch

FIX:

Edit cron jobs so that if they are dependant on the sucess of each other, they do not assume the sucess of operation.