Kbase P92101: Webspeed Workshop 'OS Commands' utility shows time as 1 hour ahead of system time
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  24/04/2009 |
|
Status: Unverified
SYMPTOM(s):
Using J2RE 1.3.1 IBM AIX build ca131-20031105.
Using WebSpeed Workshop 'OS Command' utility to run UNIX 'date' command returns the wrong time.
The time displayed though WebSpeed is 1 hour ahead of the system time.
TZ (Timezone) is set correctly on the system, and in the ubroker.properties file.
FACT(s) (Environment):
IBM AIX
Progress 9.1D
WebSpeed 3.1D
CAUSE:
This is caused by a Java bug.
FIX:
Upgrade to the latest release of JRE 1.3.1.