Consultor Eletrônico



Kbase P90721: SonicESB adapter cannot connect to OpenEdge Appserver
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   26/09/2004
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.x

SYMPTOM(s):

SonicESB cannot find OpenEdge Appserver

Web Service application not found: <Id> (10858)

CAUSE:

Runtime Properties for AppServer have not been defined in OpenEdge Resource Editor

FIX:

Open the OpenEdge Resource Editor within the SonicESB Explorer and configure
the Runtime Properties for the AppServer.