Kbase P89371: Error 7189 seen with ActiveX client receiving a temp-table
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/16/2008
Status: Unverified

FACT(s) (Environment):

Progress 9.1D

SYMPTOM(s):

Progress 9.1D08

ActiveX client and prowin32.exe client connecting to same AppServer

ActiveX client calls remote procedure which returns temp tables

prowin32 client calls remote procedure which returns temp tables

ActiveX attempts the same call again but this raises an error

Stream protocol error tag = <>. (7189)

Stream protocol error tag = 89. (7189)

CAUSE:

Due to -mc being used on the prowin32 client. Without this parameter the error is not seen.

FIX:

Upgrade to 9.1E
Upgrade to 10.0b01 or higher
As a workaround:
Remove the -mc parameter on the prowin32 client.