Kbase 16879: Progress/400 Data Dictionary Unable To Modify Attribute
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/15/2008
Status: Verified

FACT(s) (Environment):

Progress/400 DataServer

SYMPTOM(s):

When using the Progress/400 Data Dictionary tool in "MODIFY SCHEMA" mode, a message stating that the table can not be mantained via the dictionary, can be seen.

CAUSE:

This message means that the respective file or its indexes (logical files) contains AS/400 specific attributes that the Progress/400 Data Dictionary does not support.

FIX: