Consultor Eletrônico



Kbase P85699: Data Logic Procedure Fails To Run First Time On The Web
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   16/10/2008
Status: Unverified

FACT(s) (Environment):

Dynamics
OpenEdge 10.0A

SYMPTOM(s):

Data Logic Procedure Fails To Run First Time On The Web

The Data Logic Procedure fails to run for a sdo on the Web when there is more than one sdo

The Data Logic Procedure that is run is selected by alphabetic order of the sdo name, if there are two sdos called a.w and z.w then a.w's data logic procedure will run.

CAUSE:

Bug #20040624-006

FIX:

Upgrade to 10.0B