Consultor Eletrônico



Kbase P81523: TCP error 3426 when connected to AS/400
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   24/05/2004
Status: Unverified

FACT(s) (Environment):

IBM AS/400 (RISC)

FACT(s) (Environment):

Progress/400 DataServer

SYMPTOM(s):

TCP error 3426 when connected to AS/400

Clients disconnect with errors 735 and 778

** Incomplete write when writing to the server. (735)

Error <read/writing> socket, ret=<n>, errno=<n>. (778)

Escape message CEE9901 in the PROSERVER joblog on the AS/400

PRO9036: TCP Error 3426 Encountered at line #

TCP Error 3426: A connection with a remote socket was reset

The AS/400 is optimized for performance

CAUSE:

Network device problem. In particular the exact cause might be a faulty switch.

FIX:

Replace defective network device.