FACT(s) (Environment):
IBM AS/400 (RISC)
FACT(s) (Environment):
Progress/400 DataServer
SYMPTOM(s):
TCP error 3426 when connected to AS/400
Clients disconnect with errors 735 and 778
** Incomplete write when writing to the server. (735)
Error <read/writing> socket, ret=<n>, errno=<n>. (778)
Escape message CEE9901 in the PROSERVER joblog on the AS/400
PRO9036: TCP Error 3426 Encountered at line #
TCP Error 3426: A connection with a remote socket was reset
The AS/400 is optimized for performance
CAUSE:
Network device problem. In particular the exact cause might be a faulty switch.
FIX: