Consultor Eletrônico



Kbase P80629: Unable to start AdminServer after enabling Fathom remote monitoring
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/11/2004
Status: Unverified

FACT(s) (Environment):

Progress 9.1D

SYMPTOM(s):

Unable to start AdminServer after enabling Fathom remote monitoring

AdminServer fails to start with Fathom remote monitoring enabled

AdminServer fails to start with error:

java.net.MalformedURLException: no protocol: Files/Fathom (7900)

Message (throw): RegistryManager: Bind failed

Message (excp): RemoteException occurred in server thread; nested exception is:
java.rmi.UnmarshalException: error unmarshalling arguments; nested exception is:
java.net.MalformedURLException: no protocol: Files/Fathom

java.rmi.ServerException: RemoteException occurred in server thread; nested exception is:

Fathom Replication is installed on the machine

CAUSE:

Fathom Replication has been installed to a directory with spaces.

Since AdminServer reads CLASSPATH where the replication .jar files are present during startup, it can't process due to spaces in the path - that's a Sonic MQ 5 framework limitation.

FIX:

Unistall Fathom Replication and install it to a directory without spaces.