FACT(s) (Environment):

Progress 9.1D

FACT(s) (Environment):

WebSpeed 3.1D

SYMPTOM(s):

Unable to start the broker

Unable to locate shared temp-table or work-table definition for table tagmap in procedure web/objects/web-util.p. (1429)

9.1C is on the same machine

uses .pf to connect to 8.3D database

CHANGE:

upgraded to 9.1D

CAUSE:

The pf file contained the -p parameter to web-disp.p using a fully qualified path name which pointed to the 9.1C installation.

FIX: