Consultor Eletrônico



Kbase P79723: Fathom Management reports that new disk in array needs defining
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   8/10/2004
Status: Unverified

FACT(s) (Environment):

Fathom Management 2.x

SYMPTOM(s):

Fathom Management, disk replacement

A disk was replaced (hot swap) in a mirrored and striped array

Fathom Management reports that this disk needs defining

Fathom Management showing that there is a new disk to be configured

Server has not been rebooted

CAUSE:

Disk crashed and has been removed and replaced. After the disk was replaced it was assigned a new name and the machine was not rebooted. Fathom Management is reporting that this change needs to be configured.

FIX:

There are two ways to fix this:

Preferably, Reboot the machine after hot swapping the new disk and re-naming it on the disk array

Alternatively, Fathom Management needs to re-set the new disk

STEPS:
[RESOURCES] -> <select> -> "delete" the resource that was removed
[RESOURCES] -> "disks discover" new one to identify the new disk