Consultor Eletrônico



Kbase P79297: Dyn 2.1A: Strange case with SDB out of synch with other objects
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   5/5/2004
Status: Unverified

FACT(s) (Environment):

Dynamics 2.1A

SYMPTOM(s):

Moving in a SDB does not keep a viewer and navigation toolbar synchronized

Using the navigation toolbar buttons repairs the situation

Dynamics 2.1A02

Dynamics 2.1A01

CAUSE:

The real cause of this problem has not been identified at the time of writing:
Scenario seen with this problem:
Page 0 with StandardToolbarA navigation source of SDOa
Page 2 with SDOa + SDBa
Page 3 with SDVa SDOb SDVb SDBb StandardToolBarB navigation source of SDOb
+ SDOa is datasource of SDOb

Going to Page 3 with Page 2 not initialized yet. Dynamics is smart enough to start SDOa because required parent of SDOb, but the SDOb seems to not working correctly with its linked objects.

Selecting Page 2 repairs the problem

This problem could not be reproduced outside of the application that hit it.

FIX:

Initializing page 2 and 3 with container property initialPageList set to "2,3" solved the problem