Consultor Eletrônico



Kbase P77329: The WebSpeed application is pointing to the wrong database
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   08/09/2004
Status: Unverified

FACT(s) (Environment):

WebSpeed 3.x

SYMPTOM(s):

The WebSpeed application is pointing to the wrong database

One broker is connected to the production database and the other broker is connected to the test database

The agent's propath for the source code are different

The source code is identical in both environment

The production broker is set to run as a default broker

The test application is being run without the WService=<AppServiceNameList> parameter in the URL

CAUSE:

The parameter "WService=<AppServiceNameList>" is not being used in the URL when test application is run. Since the Production WebSpeed broker is run as a default service, it is running the production application which is similar application as the test application.

FIX:

Specify "WService=<AppServiceNameList>" parameter in the url to specify the correct broker.