Kbase P76813: SYSTEM ERROR 10612 due to different BI cluster size on standby and production
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   7/9/2009
Status: Verified

SYMPTOM(s):

SYSTEM ERROR: numlive 2 tx_count 2logTxEntry transnum 1788997817 rlcounter 51
pTranEntry transnum 0 rlcounter 0rlmemchk: transaction table mismatch. (10612)

SYSTEM ERROR: numlive tx_count logTxEntry transnum rlcounter
pTranEntry transnum rlcounter rlmemchk: transaction table mismatch. (10612)

BI Cluster size set differently on standby database than on production database.

In standby log file: Before-image cluster size set to 16 kb. (1620)

In production log file: Before-image cluster size set to 16384 kb. (1620)

FACT(s) (Environment):

All Supported Operating Systems
Progress 9.x
OpenEdge 10.x
OpenEdge Category: Database

CAUSE:

A truncate bi should never be run on the standby database, unless no new roll-forward will be done on that database.

FIX:

Do not run truncate bi on the standby database anymore.