Kbase P75175: Roundtable. Access violation causes Dynamics Roundtable upgrade from 10.0A or Dynamics 2.1A01 to fai
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  28/03/2006 |
|
Status: Unverified
FACT(s) (Environment):
OpenEdge 10.0A
Dynamics 2.1A01
SYMPTOM(s):
Roundtable. Access violation causes Dynamics Roundtable upgrade from 10.0A or Dynamics 2.1A01 to fail
CHANGE:
When the Dynamics DCU utility is run while upgrading a Dynamics Roundtable workspace from 10.0A or Dynamics 2.1A01, the session terminates with a memory violation error.
CAUSE:
The error seems to occur at the following statement:
segd = prncodd->pcrdir->ecsDesc
The value of prncodd->pcrdir is 0xdddddddd.
FIX:
This issue will be fixed in OpenEdge 10.1B