Consultor Eletrônico



Kbase P60414: Unable to read socket error 778 with return code 10054 and error number 2
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   08/06/2004
Status: Verified

FACT(s) (Environment):

MS SQL DataServer

FACT(s) (Environment):

Progress 9.x

FACT(s) (Environment):

Procontrol spawning MSS broker

SYMPTOM(s):

Unable to read socket error 778 with return code 10054 and error number 2

error reading socket, ret=10054, errno=2 (778)

The DataServer log showed that the dataserver was trying to write to the event log and could not

CAUSE:

The event log was full and it was not set to overwrite when necessary.

FIX:

If the event log can be overwritten set it's proprieties to "overwrite events as needed".

Else the users must monitor the event log to verify it will not be full when the
DataServer must write to it.