Consultor Eletrônico



Kbase 16531: AS/400 PROSET Causes Error in 8.0C
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   15/10/2008
Status: Verified

FACT(s) (Environment):

Progress 8.0C
AS/400 DataServer

SYMPTOM(s):

PROSET

** File <file>--File primary Index's File-recid does not match File. (162)

CAUSE:

There is a problem in using the PROSET file to exclude select/omit logical files from the server schema. The Progress error 162 will appear on the client during the Synchronize process portion of building the client schema holder. The error will result in an incomplete schema holder on the client. The error does not list the names of the files that are involved. This is bug# 96-12-12-001 and
only affects version 8.0C.

FIX:

It has been fixed in 8.0C10 and later.