Kbase P63900: Error 8406 when trying to upgrade database
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  1/22/2004 |
|
Status: Unverified
FACT(s) (Environment):
Progress 9.1x
SYMPTOM(s):
Error 8406 when trying to upgrade database
Database minor version mismatch. Expected <version>. Found <version>. (8406)
Database minor version mismatch. Expected 2. Found 3. (8406)
Converting database from 9.1A05 to 9.1D. When performing prostrct repair after copying database with 9.1D the error 8406 is seen.
CAUSE:
The Environment is not set correct. The prostrct repair utility is being executed from an DOS command prompt.
FIX:
Use proenv to execute PROSTRCT REPAIR and this resolves the problem.