Kbase P997: WebSpeed 2.x -- Error 5669 is caused by incorrect PROPATH (2
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  2/5/2003 |
|
Status: Unverified
FACT(s) (Environment):
WebSpeed 2.x
SYMPTOM(s):
Error 5669 occur when starting the Workshop, pressing Files button, and clicking on the subdirectories in the file listing
The directory for node <node-id> could not be found. (5669)
The directory for node 1185 could not be found (5669)
Cannot edit, view, run or compile files in Workshop or change the directory in the files menu. If this is attempted, the following error is received:
File id 1286 not valid.
CAUSE:
WebSpeed PROPATH is set correctly and does include /webspeed/tty directory
FIX:
Remove the PROPATH from the startup scripts and run it manually from the prompt. In a UNIX ENV, make sure that the PROPATH is exported.