Consultor Eletrônico



Kbase P997: WebSpeed 2.x -- Error 5669 is caused by incorrect PROPATH (2
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   2/5/2003
Status: Unverified

FACT(s) (Environment):

WebSpeed 2.x

SYMPTOM(s):

Error 5669 occur when starting the Workshop, pressing Files button, and clicking on the subdirectories in the file listing

The directory for node <node-id> could not be found. (5669)

The directory for node 1185 could not be found (5669)

Cannot edit, view, run or compile files in Workshop or change the directory in the files menu. If this is attempted, the following error is received:

File id 1286 not valid.

CAUSE:

WebSpeed PROPATH is set correctly and does include /webspeed/tty directory

FIX:

Remove the PROPATH from the startup scripts and run it manually from the prompt. In a UNIX ENV, make sure that the PROPATH is exported.