Consultor Eletrônico



Kbase P9499: error 5898 on client machines connecting thru terminal serv
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   1/30/2003
Status: Unverified

FACT(s) (Environment):

Windows 98

FACT(s) (Environment):

Progress 9.1C

SYMPTOM(s):

error 5898 on client machines connecting thru terminal server session

Error occurred while creating CONTROL-FRAME: ActiveBar
Error performing inpage operation.
Error Code: 0x800703e7 (5898).

CAUSE:

Client connected to a Terminal Server, we'll call that TS1.
TS1 shared a copy of Progress from another Terminal Server, we'll call that TS2.
This is likely what caused the problem since the .dll was not registered on the machine it was trying to be used.

FIX:

Prox.dll copied and registered locally.