Consultor Eletrônico



Kbase P8866: The Progress/400 DataServer broker is not starting
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/15/2008
Status: Verified

FACT(s) (Environment):

Progress/400 DataServer

SYMPTOM(s):

Receiving error CPE3420 when starting an AS/400 TCP broker with STRPRONET

CPE3420 - Address already in use

The Progress/400 DataServer broker is not starting

Both version 8 and version 9 are in the same machine

The Job log shows the following error:
TCP/IP- Broker - Domain TCP/IP service-name
Address is already in use TCP/IP broker for address domain has not been started
CPE3420 - Address already in use

The port number used to start the 9.1C broker is used with version 8 broker

CAUSE:

The port number or service name that is used to start the version 8 broker is used to start the version 9 DataServer broker. Since the version 8 broker is still running with the same port number, the above error was issued.

FIX:

Use a different port that is not used by any other processes to start the new DataServer broker. The port or service name entry must be in the services file.