Consultor Eletrônico



Kbase P8527: Proutil conv89 fails with 5034 error
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/15/2008
Status: Verified

SYMPTOM(s):

proutil conv89 fails with 5034 error

Input blocking statement invalid while executing a database CREATE or REPLICATION-CREATE trigger from a RAW-TRANSFER statement. (5034)

Messages in log file are truncated

SYSTEM ERROR: Bad return from select, errno=<n>. The server may be non-existent. (5025)

Error 5025 in log file is truncated to read: stent. (5025)

Error in rss_cleanup: error code -20021 was returned by dsmContextDelete

CHANGE:

Upgraded to Progress 9.x.

CAUSE:

The bi file was not truncated prior to database conversion.

FIX:

1. Restore backup of the Progress 8.x database.
2. Truncate the bi file with Progress 8.x.
3. Convert the database: proutil dbname -C conv89

or dump and load the database instead of converting.