Consultor Eletrônico



Kbase P7800: Session hangs when referencing default buffer of global shared temp-table
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   1/20/2009
Status: Verified

SYMPTOM(s):

Session hangs when referencing default buffer of global shared temp-table

Temp-table is defined as NEW GLOBAL SHARED

Accessing the HANDLE attribute of the temp-table's default buffer

Session hangs

FACT(s) (Environment):

Progress 9.1D
All Supported Operating Systems

CHANGE:

Applied Progress Service Pack 9.1D01

CAUSE:

Bug# OE00069234

CAUSE:

Due to a bug, an infinite loop occurs when trying to retrieve the buffer handle. It surfaced in 9.1D Service Pack 1 as a result of other bug fixes.

FIX:

Upgrade to 9.1D Service Pack 02 or higher.