Consultor Eletrônico



Kbase P7464: Apply the ai files to the restored database fails with error 505
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   09/12/2008
Status: Verified

SYMPTOM(s):

Trying to roll forward AI extents.

Invalid after image version number found in AI file header (752)

FACT(s) (Environment):

This is not a Progress AI file (756)
All Supported Operating Systems
Progress/OpenEdge Product Family
AI file cannot be used with this database. (508)
Invalid block size in AI extent header found 16384, expected 8192 (505)

CAUSE:

The database from which the AI files originates has a different AI blocksize than the destination database. If the AI blocksize is changed on the production database, ai files generated from this point on can only be rolled forward against a database with the same aiblocksize.

FIX:

Since the ai blocksize expected by restored database must match the live database, either a new probkup needs to be taken to re-establish the roll forward baseline or a previous backup that was taken AFTER the ai blocksize was changed on the origination database.