Consultor Eletrônico



Kbase P7122: 1124 error messages caused by memory corruption.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   22/03/2005
Status: Verified

SYMPTOM(s):

Database crashes.

Corrupt block detected when attempting to release a buffer. (4232)

SYSTEM ERROR: wrong dbkey in block. Found <dbkey>, should be <dbkey2> (1124)

Analysis of protrace file shows problem occurs when releasing a memory buffer.

Database scan using DBRPR does not report any data corruption on disk.

CAUSE:

Memory corruption on box.

FIX:

Reboot box to temporarily clear system's memory cache and/or disk cache.
Run memory diagnostics on system and contact operating systems manufacturer.