SYMPTOM(s):

The setup routines for the Intersolv 3.00 32-bit SQL Server ODBC driver could not be loaded due to system error code 126

OpenLink ODBC Setup
Connection Unsuccessful
CONNECTION ERROR:[OPENLINK][ODBC]Unable to allocate server handle, SQLSTATE=S1000

FACT(s) (Environment):

All Supported Operating Systems
Progress 9.x
OpenEdge 10.x

CAUSE:

An incorrect ODBC driver (SQL Server version) was being used to attempt to connect to a Progress database

FIX:

OpenLink Software provides ODBC drivers for use with Progress Software databases as well as many other databases. OpenLink maintains a Web page relating to Progress database specific connection advice at:

Vist the Openlink Knowlegebase http://support.openlinksw.com and select: Knowlege Base > Database Specific Issues > Progress