Consultor Eletrônico



Kbase P6000: Progress command not executing when DLC is not set correct i
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   09/09/2003
Status: Verified

FACT(s) (Environment):

Windows 32 Intel

FACT(s) (Environment):

Windows NT 32 Intel/Windows 2000

SYMPTOM(s):

Progress command does not execute

'proutil' is not recognized as an internal or external command, operable program or batch file

'the command' is not recognized as an internal or external command, operable program or batch file

Performing command: proutil db-name -C truncate bi

Error occurs when using any Progress command

Progress command executed within Command Prompt / DOS prompt

DLC environment variable is set at the system level

CAUSE:

The DLC environment variable is not set correctly

FIX:

Use the Progress PROENV session. This will automatically set the correct Progress environment variables, including DLC.