Kbase P52710: Dynamics Errors 3135 7351 and 3140 after upgrade to Dynamics
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  12/9/2003 |
|
Status: Unverified
FACT(s) (Environment):
Dynamics 2.1A
SYMPTOM(s):
Errors 3135 7351 and 3140 after upgrade to Dynamics 2.1A
Invalid widget-handle. Not initialized or points to a deleted widget. (3135)
BUFFER-FIELD rowobjecttable was not found in buffer print_design. (7351)
Cannot access the screen-value attribute because the widget does not exist. (3140)
After upgrade to Dynamics 2.1A from 2.0A, running containers results in several errors.
CHANGE:
Migrated from Dynamics 2.0A to 2.1A
CAUSE:
Migration procedures have picked up the orphan data that was not actually being used prior to the upgrade, and are hence inadvertently changing the behavior of some objects as a result in the migrated repository database.
FIX:
Remove the orphan data in the 2.0A repository database prior to migration to the 2.1A. For additional information please refer to the Solution P57894