Kbase P51150: AppServer is not responsive with error 9407 on the log file
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   17/03/2010
Status: Verified

SYMPTOM(s):

AppServer is not responsive with error 9407 on the log file

Application Service <Application Service> not found at NameServer at Host <Host> Port <Port>. (8245)

Name Server at Host <Host> Port <Port> is not responsive. (8239)

Connection failure for host localhost port <port> transport TCP. (9407)

FACT(s) (Environment):

Running AppServer in the same machine as the databases
All Supported Operating Systems
Progress 9.x
OpenEdge 10.x

CAUSE:

The exact cause is unknown at the time of this writing

FIX:

Remove -S -N and -H parameter from the connection of the AppServer to the database