Consultor Eletrônico



Kbase 15930: Roundtable cannot connect to database, new PDBase object.
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/05/1998
Roundtable cannot connect to database, new PDBase object.

After adding a database to Roundtable as a new PDBase object it is
neccessary to click the "OK" button at the top right hand corner of
the screen before choosing the Schema Load menu item. If Schema Load
is chosen first then Roundtable will display an error that it cannot
connect to the database. The only way to resolve the issue is to
delete the new PDBase object (which is WIP- Work In Progress) and
start over.

Other things to check are:
1.) Connection parameters. Make sure that you are using all of the
connection parameters that are required and that they are upper or
lower case as needed (such as -N, -S, -H). You will also need -U and
-P.

2.) The database needs to be in the appropriate directory. The
Workspace Drive and directory are where it needs to be (the Source
directory in the Product Module setup screen is not used for PDBase
objects).

Progress Software Technical Support Note # 15930