Consultor Eletrônico



Kbase P45660: What SHUTDOWN parameters may be used in Procontrol for a database?
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   27/12/2010
Status: Verified

GOAL:

What SHUTDOWN parameters may be used in ProControl for a database?

FIX:

The following parameters are valid in the SHUTDOWN parameter input box for ProControl.

-by
Performs an unconditional batch shutdown and disconnects all active users. Note: notice is not given to users before disconnecting them.

-F
Starts an emergency shutdown. This parameter may only be used on the machine where the server resides. This parameter is not applicable for remote
shutdowns.

-H host-name
Specifies the machine where the database server runs. If issuing the shutdown command from a remote machine, specify the host name.

-S service-name
Specifies the database server or broker process. If issuing the shutdown command from a remote machine, specify the service name.

-cpinternal codepage
An internationalization startup parameter that identifies the code page used in memory.

-cpstream codepage
An internationalization startup parameter that identifies the code page used for stream I/O.

NOTE: The information above is not documented in any book.
ProControl was a tool designed in Progress 8 and is currently included in Progress 9. However, it is recommended that the Progress Explorer tool be used in Progress 9 as ProControl will go away in the future and Progress Explorer is the currently supported tool for maintaining databases.