Consultor Eletrônico



Kbase P44376: A Web Services application stopped running
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/16/2008
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.0x

SYMPTOM(s):

A Web Services application stopped running

Error 10893 appears

An error was detected while executing the Web Service request. (10893)

CAUSE:

The Wrong AppService name was specified in the Web Service definition.

FIX:

Correct the AppService name in the Web Service proxy.

There are 2 ways to achieve this:
- Regenerate the Proxy via the Proxy Generator (ProxyGen) with the correct AppService name

or

- Disable the Web Service from the Progress Explorer
- Modify the "appServiceName" property of the Web Service