Consultor Eletrônico



Kbase P43788: OpenEdge BETA: AppBuilder starts with error 5893
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   12/04/2005
Status: Unverified

FACT(s) (Environment):

OpenEdge 10.0A
Windows
Progress 9.1D

SYMPTOM(s):

OpenEdge 10.0A Beta

AppBuilder starts with error 5893

The automation server for <automation object name> is not registered properly.
Please reinstall this server or try registering it again. (5893)

The automation server for PROX.PROIDE is not registered properly.
Please reinstall this server or try registering it again. (5893)

Occurs if only OpenEdge Studio is installed

Does not occur if previous Progress Release (ie. 9.1D) is installed.

CAUSE:

Bug# 20030923-019

CAUSE:

Depending on the products installed, the installation utility does not properly register <install-dir>\bin\prox.dll for OpenEdge.

FIX:

Upgrade to 9.1D08 or OpenEdge 10.0A FCS release.

Workaround:
Manually register <install-dir>\bin\prox.dll (using the Windows regsvr32 command)