Kbase P3996: AppServer on HP-UX 11 fails to start with errors 5513, 8113, 8117, 8100
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/15/2008
Status: Verified

FACT(s) (Environment):

Progress 9.1C
Progress 9.1D
HP-UX 11.0 32-bit

SYMPTOM(s):

AppServer on HP-UX 11 fails to start with errors 5513, 8113, 8117, 8100

<component_name> was unable to create log file <logfile_path>. (5513)

Message from server : Application Server was unable to create log file /usr/wrk91d/appstat.server.log. (5513) (8113)

IOException reading message from server : java.io.EOFException: pipe to server broken (8117)

ERROR: cannot start server. (8100)

Can start and query the AdminServer and NameServer.

CAUSE:

There is an interdependency between 32-bit Progress for HP-UX and the HP-UX patch PHSS_22543 PHSS_22478, and its successors. These are required to run 9.1C and 9.1D on HPUX 11.

FIX:

Please refer to Progress Solution P16085 "What OS patches are required for 9.1C and 9.1D to run on HP-UX 11?" for information on required HPUX 11 patches for 9.1C and 9.1D. Installed patches can be verified with the "swlist" command.