Kbase P39468: 30 seconds delay in loading PStimer OCX control
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   9/23/2003
Status: Unverified

FACT(s) (Environment):

Progress 8.3x

FACT(s) (Environment):

Windows 2000

SYMPTOM(s):

30 seconds delay in loading PStimer OCX control

Problem only occurs at initial loading time

Able to isolate the code to this line

uib_s=chctrlframe:loadcontrols(ocxfile,"ctrlframe",u)

PSTimer loads fast if there is no database connection.

Recently a disk failed on a networked test Server that at one time held the Production Progress application.

CAUSE:

The registry on the client machine had a path to the failed non existing Server.

FIX:

Delete any references to the failed non existing server and ensure that the PROPATH correctly points to the live server and its directories.