Kbase P33312: Error 6019 and 6275 running WebSpeed Using Old ubroker.properties file
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  10/15/2008 |
|
Status: Verified
FACT(s) (Environment):
WebSpeed 3.x
SYMPTOM(s):
Error 6019 and 6275 running WebSpeed
WebSpeed error from messenger process (6019)
<opname> failed: WebSpeed error <ws_error>, System error <errno>, <errordesc> (6275)
getPropValue for keyword RootPath failed: WebSpeed error 10010, System error 0, Specified Keyword Value is invalid (6275)
Using the ubroker.properties from WebSpeed 3.1C with the current installation of WebSpeed 3.1B
The RootPath and ScriptPath in the ubroker.properties file are pointing to wrong directory
CAUSE:
The Old ubroker.properties' RootPath and the ScriptPath under the [WebSpeed] section are pointing to the wrong folders.
FIX:
Enter the correct path for RootPath and the ScriptPath under the [WebSpeed] section of the ubroker.properties file.